Single Phase - Dry Type - 1 - 150 KVA
Power Conditioner is a combination of Servo Controlled Voltage Stabiliser and Ultra Isolation Transformer. It is designed to protect sensitive equipment from all type of Power disturbances such as input voltage fluctuations and Electrical noise generated by breakers, Heavy duty Machineries, Capacitor Panels, induction hardening, Cranes, Welding etc. The use of inverters, Drives, Switching power supplies further polluted the electrical environment, causing severe supply problems to load like CNC machines, Medical equipment, Computers, Communication Equipment and Lightings etc. NEELKANTH make POWER CONDITIONER is the solution for these problems and eliminates major electrical disturbances and p rovides clean Supply to the Loads.
| Type | KVA Ratings | Model | Servo Motor | Input Voltage Range (VAC) |
Output Voltage (VAC) |
|---|---|---|---|---|---|
| 1 Phase Air Cooled | 1 – 50 KVA | PD – XXX PA – XXX |
PMDC AC Synchronous | 170 - 270 | 230 / 110 |
a) Please contact our sales and application engineers for further guidance
b) Non-Standard Input Voltage Range and Output Voltages are also available on request
| Regulation | 2 - 4 % |
| Response Time | < 10 m.sec |
| Rate of Correction | Up to 105 V / Sec & Up to 70 V / Sec |
| Combined Efficiency | Better than 97 %. |
| Frequency | 47 – 53 Hz. |
| Common Mode Noise Rejection | Better than 80 - 100dB / 120dB or as required. |
| Coupling Capacitance | Better Than 0.1 / 0.01pF or as required. |
| Duty | 100% Continuous. |
| Effect of Load Power Factor | Nil |
| Wave form Distortion | Nil (Same as input) |
| Harmonic Distortion | None |
| Line and Load | phase sensing and control provides for 100 % load variations within the rating of equipment |
| MCB | At Incoming for Over Load and Short circuit protection. |
| Control Panel | Auto / Manual controls |
| Output Voltage Protection. | Electronics Adjustable Output Under and Over Volt. Alarm / time Delay Circuit with Output Voltage Trip. |
| Servo Motor Protection | Cut-off for Servo Motor at Input Under/Over volts |
| Cooling | Air Cooled |
| Environment | Temperature range – 0 to 45 °C. Suitable for indoor Tropical use 90% RH (non-condensing) |
| Construction | IP21 Rugged Construction / Caster wheels for easy movements |
| Color | Std. RAL – 7035 (Grey) / other on request. |
| MTBF | Mean Time Between Failure – Better than 43,800 Hrs |
- Full function Auto / Manual controls
- Low losses & Best Efficiency up to 97 %.
- Highest Rate of correction.
- Best Response time.
- Voltmeter for Input & Output Voltage.
- High Torque low inertia Motor with Proportional Control.
- Output under & Over Voltage LED for Fault indication.
- Common Mode Noise Rejection upto120dB.
- Coupling Capacitance better than 0.1/0.01pf.
- Advanced electronic circuits to maintain constant output voltage on DG.
- Electronics Output Over Load.
- Input Under and Over Voltage indication and Cut off
- High Low Frequency Cut off.
- Ground Fault Monitoring with Trip and Indication.
- Surge Suppressor (Metal Oxide Varistor)
- Surge Protective Device 8/20 micro sec. as per IEC 61000-4-4 / 61000-4-5.
- Auto Start with time delay.
- Stabiliser By pass Switch
- Other Color (specify RAL shade number)
Typical schematics for product installation
- # Non-Standard KVA, Input and Output Voltage are also available on request.
- # NEELKANTH reserves the rights to amend design and specification without notice as continuous efforts are Made To improve product performance.
- # Some of the features are optional depend on order.
- Medical Diagnostic Equipment
- Electronic Equipment
- Lab Equipment
- Pharmaceuticals Machine
- Textile Machinery
- Process Controls
- Elevators
- Cold Storage
- Hospitals
- Residential