Furnace Transformer - Induction & Melting
Furnace Transformers are used to supply power where there are high current requirements to electric furnaces of the induction, resistance, open arc, and submerged-arc types.
The secondary of furnace Transformers are generally low voltage are with high harmonics withstanding capacity.
| Heating | Steel Plant | Rolling mills |
| Various Industries like mining, cement. | Non Ferrous Metal Industries. | Heavy Engineering |
| Parameter | Description |
|---|---|
| KVA Rating – Three Phase | 50 to 2500 KVA |
| Cooling | Air & Oil Cooled. |
| Input Voltage | 415 - 3 Phase or as required. |
| Output Voltage | Up to 100 V or as required. |
| Construction | Double wound, Common core, Varnish and vacuum impregnated. |
| Winding | Electrolytic grade Copper |
| Frequency | 50 +/- 3 Hz / 60 Hz on request. |
| Insulation Class / Level | F Class / 155 deg. C & H Class / 180 deg. C |
| Maximum temperature rise | 115 deg. C. |
| Efficiency | Better than 97 %. |
| Regulation | 2 – 4 % or as required. |
| Galvanic Insulation | Better than 500 / 1000 Mega-Ohms - DC Isolation @ 2500 V |
| High Voltage Breakdown Test | 2.5 KV for one Minute Between windings and Earth. |
| Termination Type | Terminal Board / Stud – Bolts / Bus Bar |
| Enclosure Protection Class | IP21 / As per Requirement. |
| Enclosure Finish | Siemens Gray, RAL 7035 (Other color available on request). |
| Environment | Temperature Range 0 to 45 °C. Suitable for indoor Tropical use 90% RH (non-condensing). |
| Reference Standard | IS2026 / IS11171 |
| Life Expectancy | 25 Years |
- High Cross Section.
- Use of Multi-stranded Copper conductor to reduce Eddy current losses.
- Use of High permeability, low losses electrical steel.
- Provide electrostatic earth shield between windings to protect rectifier elements against line voltage surges.
- Cores designed for reduced flux densities to compensate for harmonic voltage distortion.
- Very High currents as compared to Conventional transformers.
- Large low voltage variation to suit furnace application.
- Withstand harmonics generated due to rectifier, furnace operation
- Medical Diagnostic Equipment
- Electronic Equipment
- Lab Equipment
- Pharmaceuticals Machine
- Textile Machinery
- Process Controls
- Elevators
- Cold Storage
- Hospitals
- Residential
- Ammeter for Load Current.
- Input Under and Over Voltage indication and Cut off
- Electronics Output Over Load.
- Ground Fault Monitoring with Trip and Indication / Earth leakage.
- Surge Suppressor (Metal Oxide Varistor)
- Surge Protective Device 8/20 micro sec. as per IEC 61000-4-4 / 61000-4-5.
- Stabiliser By pass Switch
- Auto Start with time delay.
Typical schematics for product installation
- # Non-Standard KVA, Input Voltage Range and Output Voltages are also available on request.
- # NEELKANTH reserves the rights to amend design and specification without notice as continuous efforts are Made to Improve product performance.
- # Some of the features are optional depend on model and as per order.