Rectifier Transformer
Rectifier transformers are used for industrial processes which requires significant high current like electrochemical processes like chlorine production, Electrolysis processes for the production of aluminum where harmonic current are generated. Rectifier Transformers are also used to supply power where there are high current requirements as in Electroplating systems.
The secondary of these Transformers are generally low voltage with high current and are with high harmonics withstanding capacity.
| Electrolysis Process. | Electroplating | Smelting Operation |
# Non-Standard KVA, Input and Output Voltage are also available on request.
# NEELKANTH reserves the rights to amend design and specification without notice as continuous efforts are Made toImprove product performance.
# Some of the features are optional depend on order.
| Parameter | Description |
|---|---|
| KVA Rating – Three Phase | 50 to 5000 KVA |
| Cooling | Air & Oil Cooled. |
| Input Voltage | 415 - 3 Phase or as required. |
| Output Voltage | Up to 100 V or as required. |
| Construction | Double wound, Common core, Varnish and vacuum impregnated. |
| Winding | Electrolytic grade Copper |
| Frequency | 50 +/- 3 Hz / 60 Hz on request. |
| Insulation Class / Level | F Class / 155 deg. C & H Class / 180 deg. C |
| Maximum temperature rise | 115 deg. C. |
| Efficiency | Better than 97 %. |
| Regulation | 2 – 4 % or as required. |
| Galvanic Insulation | Better than 500 Mega-Ohms - DC Isolation @ 2500 V |
| High Voltage Breakdown Test | 2.5 KV for one Minute Between windings and Earth. |
| Termination Type | Terminal Board / Stud – Bolts / Bus Bar |
| Enclosure Protection Class | IP21 / As per Requirement. |
| Enclosure Finish | Siemens Gray, RAL 7035 (Other color available on request). |
| Environment | Temperature Range 0 to 45 °C. Suitable for indoor Tropical use 90% RH (non-condensing). |
| Life Expectancy | 25 Years |
- High Torque Low Inertia Motor with Proportional Control.
- High Rate of Correction.
- Response time less than 10 m seconds.
- Low losses. Efficiency better than 98 %.
- Full function Auto / Manual & Lower Raise controls.
- Voltmeter for Input & Output Voltages.
- Output under & Over Voltage LED for Fault indication.
- Advanced electronic circuits to maintain constant output voltage even on DG.
- Medical Diagnostic Equipment
- Electronic Equipment
- Lab Equipment
- Pharmaceuticals Machine
- Textile Machinery
- Process Controls
- Elevators
- Cold Storage
- Hospitals
- Residential
- Ammeter for Load Current.
- Input Under and Over Voltage indication and Cut off
- Electronics Output Over Load.
- Ground Fault Monitoring with Trip and Indication / Earth leakage.
- Surge Suppressor (Metal Oxide Varistor)
- Surge Protective Device 8/20 micro sec. as per IEC 61000-4-4 / 61000-4-5.
- Stabiliser By pass Switch
- Auto Start with time delay.
Typical schematics for product installation
- # Non-Standard KVA, Input Voltage Range and Output Voltages are also available on request.
- # NEELKANTH reserves the rights to amend design and specification without notice as continuous efforts are Made to Improve product performance.
- # Some of the features are optional depend on model and as per order.